partial replacement of fine aggregate using copper slag in concrete

partial replacement of fine aggregate using copper slag in concrete

partial replacement of fine aggregate using copper slag in concrete
Application

Partial Replacement of Copper Slag as Fine Aggregate Partial Replacement of Copper Slag as Fine Aggregate Ambrish E1, Dhavamani Doss S2, ShanmugaNathan N3, con

partial replacement of fine aggregate using copper slag in concrete

  • Partial Replacement of Copper Slag as Fine Aggregate

    Partial Replacement of Copper Slag as Fine Aggregate Ambrish E1, Dhavamani Doss S2, ShanmugaNathan N3, concrete with partial replacement of fine aggregate by copper slag with various percentages of 0%, 10%, 15% and 20% The specimens were casted for 7days, 14 days and 28 days then tested The results are presented above V REFERENCES [1] AlJabri, K and Makoto Hisada “Copper slagThe concrete was prepared for the M20 grade concrete with partial replacement of fine aggregate by copper slag with various percentages of (0%, 5%, 10%, 20%, 30%, 40% and 50%) The specimens were casted for 7 days, 14 days and 28 days then tested the optimum value which provided the best performance was at 40% addition of copper slag for split tensile strength test The optimum(PDF) Partial Replacement of Copper Slag as Fine AggregateInfluence of Copper Slag in Concrete as Partial Replacement for Fine Aggregate N Vinoth Kumar1 S K Divya2 A Sattainathan Sharma3 1,2,3Assistant Professor 1,2,3Department of Civil Engineering 1,2,3Valliammai Engineering College, Kancheepuram, India Abstract—Concrete is the widely used construction material In which fine aggregate is one of the important constituents An experimentalInfluence of Copper Slag in Concrete as Partial

  • (PDF) Partial Replacement of Copper Slag as Fine Aggregate

    Abstract and Figures this project present the usage of copper slag for the partial replacement for fine aggregate the experimental procedure is conducted for the replacing percentage of 10%,15%Copper Slag and Flyash for Fine Aggregate and Cement and PVA Fiber As Reinforcement in Concrete A of concrete with partial and fully replacement of copper slag and partial replacement of cement by Fly Ash and its compare with controlled cubes Fine Aggregates are replaced by copper slag for various percentages 20%, 40%, 60%, 80% and 100% and cement with additionally used material ofExperimental Study on Partial Replacement of Copper SlagCopper slag is one of the materials that is considered as a industrial waste which can be used in construction Industry This paper presents the results of an experimental investigation on the properties of concrete using copper slag as partial replacement of fine aggregate For this research work, M20 grade concrete was used and tests wereEffect of Copper Slag as a Partial Replacement of Fine

  • Vol 5, Issue 12, December 2016 Effect of Copper Slag as

    Effect of Copper Slag as Partial Replacement of Fine Aggregate in Concrete: A Literature Review Abhinav Shyam1, Velumani&Maheswaristudied on Mechanical and Durability Properties of RC Beams Using Copper Slag as Fine Aggregate in Concrete Copper slag has physical properties similar to the fine aggregate, so it can be used as a replacement of fine aggregate in concrete Copper slagAbstract and Figures this project present the usage of copper slag for the partial replacement for fine aggregate the experimental procedure is conducted for the replacing percentage of 10%,15%(PDF) Partial Replacement of Copper Slag as Fine AggregateEffect of Copper Slag as Partial Replacement of Fine Aggregate in Concrete: A Literature Review Abhinav Shyam1, Velumani&Maheswaristudied on Mechanical and Durability Properties of RC Beams Using Copper Slag as Fine Aggregate in Concrete Copper slag has physical properties similar to the fine aggregate, so it can be used as a replacement of fine aggregate in concrete Copper slagVol 5, Issue 12, December 2016 Effect of Copper Slag as

  • Experimental Study on Partial Replacement of Copper Slag

    Copper Slag and Flyash for Fine Aggregate and Cement and PVA Fiber As Reinforcement in Concrete A of concrete with partial and fully replacement of copper slag and partial replacement of cement by Fly Ash and its compare with controlled cubes Fine Aggregates are replaced by copper slag for various percentages 20%, 40%, 60%, 80% and 100% and cement with additionally used material of· The objective of the present study is to utilize high volume copper slag (ie 100%) as a replacement to fine aggregate and partially replacing cement with Nano silica The work is carried out in two phases In the first phase, the fine aggregate is replaced with copper slag in different percentages of 20%, 40%, 60%, 80%, and 100%Effect of copper slag as fine aggregate replacement in· This work focuses on the use of copper slag, as a partial replacement of sand for use in cement concrete and building construction Cement mortar mixtures prepared with fine aggregate made up of different proportions of copper slag and sand were tested for use as masonry mortars and plastering Three masonry wall panels of dimensions 1 × 1 m were plastered The studies showed thatStudies on use of Copper Slag as Replacement Material for

  • Study on Strength of High Performance Concrete by Partial

    Study on Strength of High Performance Concrete by Partial Replacement of Fine Aggregate by Copper Slag JVengadesh Marshall Raman 1, RRajesh 2, PSabari Velswaran 3 1 R&D Coordinator, 2,3 Student, Department of Civil Engineering Mailam Engineering College, Mailam, Villupuram District, Tamil Nadu 604 304, India ABSTRACT The present experimental workinvestigation carried out on concrete with partial replacement of fine aggregate by copper slag, Concretemixes, viz Conventional concrete mixes with varying percentages of copper slag (10, 20, 30 and 40%) as fine aggregate replacement material were investigated The compressive strength test was carried out on 4 concrete mixes at the ages of 7, 14 and 28 daysThe effect of copper slag asUtilization of Copper Slag in MSand as Partial· Chitra investigated on high strength concrete prepared from copper slag as fine aggregates at 40% and nanosilica up to 2% replacement Results show that very low rapid chloride permeability values at 28 and 90 days Water absorption values reduce with increment in copper slag content DebouchaEffect of iron slag as partial replacement of fine

  • copper slag as a fine aggregate ppt

    A Partial Replacement of Fine Aggregate by Copper Slag In Concrete 12 Dec 2016 Abstract: Many countries are witnessing a rapid growth in the constructionpartial replacement for fine aggregate in structural concrete is particularly attractive This project aimed to de termine the level of glass replacement resulting in optimal compressive strength Three concrete samples were tested at 7 and 28 days for glass replacement proportions of 15 20 25 30 and 40 Compressive strength ARTIFICIAL SAND role Concrete is an artificial stone resulting fromreplacement of sand by crushed concrete in pdfinvestigation on use of copper slag as partial replacement of fine aggregate in concrete Another important strength property of concrete is the flexural strength of a concrete 36 Samples were casted as per IS: 5161959 using beam size (15cm x 15cm x70cm) and 3 samples were tested for flexural strength at 7 & 28 days of curing for each mixTop PDF INVESTIGATION ON USE OF COPPER SLAG AS PARTIAL

  • Effect Of Copper Slag On Mechanical Properties Of Concrete

    Of Concrete As A Partial Replacement Of Fine Aggregate 1SPPethkar, 2RM have investigated the use of copper slag as a replacement of fine aggregate in concrete According to this study, the various strength of concrete like compressive, flexural and split tensile were studied and nondestructive test such as rebound hammer test and ultrasonic pulse velocity measurement were studied forby using copper slag as partial replacement of fine aggregate using different proportion v) To find the optimum proportion (20%, 30% & 40%) of Copper Slag that can be used as a replacement substitute material for fine aggregate in concrete International Research Journal of Multidisciplinary Science & Technology Volume: 02 Issue: 03 | April2017 wwwirjmrs ISSN : 2455930X SpecialEXPERIMENTAL STUDY ON CONCRETE BY PARTIAL REPLACEMENTConcrete mixtures were prepared using different proportions of copper slag as partial and full replacement of fine aggregate The percentage of copper slag added by weight ranged between 10 100% of sand used in concrete For each concrete mixture, six 150mmx150mmx150mm cubes, three 300mmx150mm dia cylinders and three 100mmx100mmx500mm prisms were cast Density,Copper slag as fine aggregate for high performance concrete

  • INVESTIGATION ON USE OF COPPER SLAG AS PARTIAL REPLACEMENT

    Copper slag is one of the materials that is considered as a waste which could have a promising future in construction Industry as partial or full substitute of fine aggregates For this research work, M50 grade concrete was used and tests were conducted for various proportions of copper slag replacement with sand of 0, 20%, 40%, 60%, 80% & 100% in concrete, to study the strength properties· This work focuses on the use of copper slag, as a partial replacement of sand for use in cement concrete and building construction Cement mortar mixtures prepared with fine aggregate made up of different proportions of copper slag and sand were tested for use as masonry mortars and plastering Three masonry wall panels of dimensions 1 × 1 m were plastered The studies showed thatStudies on use of Copper Slag as Replacement Material forStudy on Strength of High Performance Concrete by Partial Replacement of Fine Aggregate by Copper Slag JVengadesh Marshall Raman 1, RRajesh 2, PSabari Velswaran 3 1 R&D Coordinator, 2,3 Student, Department of Civil Engineering Mailam Engineering College, Mailam, Villupuram District, Tamil Nadu 604 304, India ABSTRACT The present experimental workStudy on Strength of High Performance Concrete by Partial

  • Research Paper To Study the Performance of Copper Slag As

    To Study the Performance of Copper Slag As Partial or Fully Replacement to Fine Aggregates in Concrete Mr Suhas S 386 N/mm2 and 542 N/mm2 for 40% replacement of fine aggregate by copper slag as compared to control mixture The ultrasonic pulse velocity test indicated the excellent quality of concrete at all percentage replacement level Therefore, it is recommended that 40% ofPROPERTIES AS PARTIAL REPLACE OF FINE AGGREGATE IN CONCRETE MIX DESIGN R R Rajaramnagar ABSTRACT: This paper reports on an experimental program to investigate the effect of using copper slag as a replacement of fine aggregate on the strength properties Copper slag is the waste material of matte smelting and refining of copper such that each ton of copper generatesResearch Paper PERFORMANCE OF COPPER SLAG ON STRENGTH· Chitra investigated on high strength concrete prepared from copper slag as fine aggregates at 40% and nanosilica up to 2% replacement Results show that very low rapid chloride permeability values at 28 and 90 days Water absorption values reduce with increment in copper slag content DebouchaEffect of iron slag as partial replacement of fine